HVAC systems can develop issues due to wear and tear, electrical problems, refrigerant leaks, or airflow restrictions. Below is a list of common HVAC problems and how to troubleshoot them.

In this article:
- 1. HVAC System Won’t Turn On
- 2. AC Not Cooling / Weak Cooling
- 3. Furnace Not Heating
- 4. Blower Motor Not Running
- 5. HVAC System Short Cycling (Turning On and Off Frequently)
- 6. Noisy HVAC Unit (Buzzing, Rattling, or Grinding Sounds)
- 7. AC or Furnace Running Constantly
- 8. Water Leaking from AC or Furnace
- 9. Bad Indoor Air Quality (IAQ) – Dust, Odors, or Mold Growth
- 10. Poor Airflow from HVAC System
- 10 Frequently askes questions on HVAC issues and fixes:
- Conclusion:
1. HVAC System Won’t Turn On
🔍 Possible Causes:
- ✔ Tripped breaker or blown fuse
- ✔ Thermostat set incorrectly or has dead batteries
- ✔ Low voltage transformer failure
- ✔ Loose wiring or faulty control board
🛠 Fixes:
- ✅ Check and reset circuit breaker.
- ✅ Replace thermostat batteries & ensure correct settings.
- ✅ Use a multimeter to check for 24V at the transformer.
- ✅ Inspect & tighten loose connections.
2. AC Not Cooling / Weak Cooling
🔍 Possible Causes:
- ✔ Dirty air filter restricting airflow
- ✔ Low refrigerant charge (leak)
- ✔ Frozen evaporator coil due to low airflow
- ✔ Faulty capacitor or compressor issue
- ✔ Condenser coils clogged with dirt/debris
🛠 Fixes:
- ✅ Replace or clean the air filter.
- ✅ Inspect refrigerant levels (call a professional if low).
- ✅ Clean evaporator & condenser coils.
- ✅ Check if capacitor is bulging and replace if needed.
- ✅ Ensure proper airflow by checking ducts & dampers.
3. Furnace Not Heating
🔍 Possible Causes:
- ✔ Dirty flame sensor (gas furnace)
- ✔ Clogged air filter restricting airflow
- ✔ Ignitor failure (electric or gas)
- ✔ Tripped limit switch (overheating issue)
- ✔ Gas valve or pilot light problem
🛠 Fixes:
- ✅ Clean the flame sensor with fine sandpaper.
- ✅ Replace the air filter.
- ✅ Test ignitor for continuity with a multimeter; replace if faulty.
- ✅ Reset high-limit switch (after checking for airflow issues).
- ✅ Ensure gas valve is open and pilot light is lit.
4. Blower Motor Not Running
🔍 Possible Causes:
- ✔ Blown run capacitor
- ✔ Bad blower relay or contactor
- ✔ Motor bearings seized
- ✔ Tripped high-limit switch
🛠 Fixes:
- ✅ Test the capacitor with a multimeter; replace if weak.
- ✅ Check blower relay for 24V signal; replace if defective.
- ✅ Try manually spinning the blower wheel; if stuck, motor may be bad.
- ✅ Reset limit switch and check for airflow blockages.
5. HVAC System Short Cycling (Turning On and Off Frequently)
🔍 Possible Causes:
- ✔ Dirty air filter causing overheating
- ✔ Oversized unit cooling too quickly
- ✔ Thermostat placement near heat sources
- ✔ Low refrigerant or clogged expansion valve
🛠 Fixes:
- ✅ Replace air filter and clean coils.
- ✅ Ensure thermostat is properly placed (not near heat sources).
- ✅ Check for refrigerant issues (professional service needed).
- ✅ Verify proper duct sizing for the system.
6. Noisy HVAC Unit (Buzzing, Rattling, or Grinding Sounds)
🔍 Possible Causes:
- ✔ Loose screws or panels
- ✔ Failing motor bearings
- ✔ Debris in blower wheel or fan blades
- ✔ Bad compressor relay or contactor
🛠 Fixes:
- ✅ Tighten loose screws & panels.
- ✅ Lubricate or replace worn-out motor bearings.
- ✅ Remove debris from blower wheel.
- ✅ Replace contactors or relays if buzzing persists.
7. AC or Furnace Running Constantly
🔍 Possible Causes:
- ✔ Thermostat set too low/high
- ✔ Stuck relay or contactor
- ✔ Leaky ducts losing conditioned air
- ✔ Dirty coils reducing efficiency
🛠 Fixes:
- ✅ Adjust thermostat to a reasonable setting.
- ✅ Test and replace stuck relays/contactors.
- ✅ Inspect ductwork for leaks and seal gaps.
- ✅ Clean condenser and evaporator coils.
8. Water Leaking from AC or Furnace
🔍 Possible Causes:
✔ Clogged condensate drain line
✔ Cracked drain pan
✔ Frozen evaporator coil (due to low airflow)
✔ Faulty condensate pump
🛠 Fixes:
✅ Clear clogged drain lines with compressed air or vinegar.
✅ Replace damaged drain pan.
✅ Check airflow issues (dirty filter, blower motor issues).
✅ Test condensate pump operation and replace if needed.
9. Bad Indoor Air Quality (IAQ) – Dust, Odors, or Mold Growth
🔍 Possible Causes:
✔ Dirty filters or ducts
✔ High humidity levels (poor dehumidification)
✔ Mold growth in evaporator coil or drain pan
✔ Leaky ducts pulling in contaminants
🛠 Fixes:
✅ Change air filters regularly (every 1-3 months).
✅ Clean coils, drain pans, and ductwork.
✅ Install dehumidifier if humidity is too high.
✅ Seal leaky ducts to prevent dust infiltration.
10. Poor Airflow from HVAC System
🔍 Possible Causes:
- ✔ Dirty or clogged air filter
A full filter restricts airflow, forcing your system to work harder. - ✔ Blocked or closed vents
Furniture, rugs, or closed registers can limit air delivery to rooms. - ✔ Leaky or damaged ductwork
Holes, disconnections, or crushed ducts leak air before it reaches the rooms. - ✔ Malfunctioning blower motor or fan
A weak, dirty, or broken fan can’t push enough air through the system. - ✔ Dirty evaporator coil or blower wheel
Dust and debris can coat coils and fans, reducing airflow efficiency. - ✔ Incorrectly sized HVAC system
Too small = not enough airflow. Too big = short cycling and uneven airflow.
🛠 Fixes:
- ✅ Replace or clean the air filter
Do this every 1–3 months depending on usage and filter type. - ✅ Ensure all vents are open and unobstructed
Check that nothing is blocking air registers. - ✅ Inspect ducts for leaks or damage
Seal small gaps with foil tape; call a pro for larger duct issues. - ✅ Clean blower motor and evaporator coil
Use compressed air or a soft brush (or hire a pro for deep cleaning). - ✅ Test and replace faulty blower motor
Listen for strange noises or weak airflow; use a multimeter to check voltage. - ✅ Have a technician evaluate system size
A Manual J load calculation can determine if your unit is appropriately sized.
10 Frequently askes questions on HVAC issues and fixes:
❓ 1. Why won’t my HVAC system turn on?
🔧 Answer: Check the thermostat settings, circuit breaker, and replace batteries. It could also be a blown fuse or faulty transformer.
❓ 2. Why is my HVAC blowing warm air when it should be cool?
🔧 Answer: Could be low refrigerant, dirty coils, or thermostat set to heat. Check settings, clean coils, and call a tech for refrigerant issues.
❓ 3. Why is airflow weak in certain rooms?
🔧 Answer: Likely due to blocked vents, duct leaks, dirty filters, or unbalanced ductwork. Clear vents and check filters first.
❓ 4. How often should I replace my HVAC air filter?
🔧 Answer: Every 1–3 months, depending on system usage, pets, and filter type.
❓ 5. What causes my HVAC system to short cycle (turn on and off quickly)?
🔧 Answer: Oversized system, clogged filter, low refrigerant, or thermostat issues. Check filter and settings first.
❓ 6. Why is there water leaking around my HVAC unit?
🔧 Answer: A clogged condensate drain line or frozen coil is often the cause. Clear the drain or check for ice buildup.
❓ 7. How can I reduce my energy bill with HVAC?
🔧 Answer: Replace filters regularly, seal ducts, program your thermostat, and schedule seasonal maintenance.
❓ 8. When should I replace my HVAC system?
🔧 Answer: Most systems last 10–15 years. Replace if repairs are frequent, performance is poor, or energy bills spike.
❓ 9. Why does my HVAC make strange noises?
🔧 Answer: Rattling = loose parts, squealing = belt issues, banging = blower/fan problems. Turn off and call a pro if unsure.
❓ 10. Is annual HVAC maintenance really necessary?
🔧 Answer: Yes! It improves efficiency, extends system life, and catches issues early before they become expensive.
Conclusion:
✔ Perform regular maintenance (clean filters, coils, drain lines).
✔ Keep vents and ducts free of obstructions.
✔ Check thermostat settings & wiring periodically.
✔ Use a multimeter to diagnose electrical issues.
✔ Schedule professional maintenance annually.